we bought a 1/4 inches valve considering that the ice manufacturer connector We have says 1/4 FCM onto it nonetheless it failed to fit. It seems similar to 1/8 inches, but a 1/8 inches valve does not fit either, even though it is quite near. Where could I find information regarding water pipeline sizes, there should be some standard?
The copper water line i will be linking it to has got the precise measurement that is same the refrigerator.
IMPROVE:
Okay I was thinking that looking the world wide web for 1/4″ OD Valve Male Female would get me personally the thing I require but i will be getting no outcomes therefore I’ve reopened issue! Can anybody provide me personally a web backlink to an item that may fit? I have added an image of this present connection where i would ike to include the valve. Many Many Many Thanks!
3 Responses 3
You will find various criteria to pipelines and threads. Your problem is you are attempting to mix two various standards that are threaded.
The ball valve which you connected to has nationwide pipeline threads (NPT). NPT are tapered also it is the fact that taper that produces the seal from a male and female joint. No washers are needed.
What exactly is shown in your picture is compression fixtures that have a right or thread that is running. The seal is created by either a ferrule or even a plastic washer.
The connection between the copper tube and the supply hose has been made as follows in your case
1/4″ Copper Tube > 1/4″ Compression by 1/4″ Compression Coupling > 1/4″ Supply Hose
The seal on the copper pipe is created by way of a ferrule this is certainly situated underneath the nut. Since the nut is tightened, the ferrule is compressed between your coupling while the pipeline.
The seal on the supply hose part is manufactured by way of a plastic washer that is often integral the the nut associated with supply hose. (The compression coupling could have include two pea pea pea nuts, certainly one of that has been discarded while the supply hose has one integrated.)
Therefore, to resolve your concern, you simply require a 1/4″ compression x 1/4″ compression valve that may change the coupling that is current. Let me reveal a website link to this kind of valve.
Do the paperwork is had by you that was included with the refrigerator? It must show the ice maker install and maybe state the scale associated with valve. I’ve constantly seen that it is 1/4″.
Where could be the water line tapped from? Often it comes down a 1/2″ copper pipeline. You can place your valve in the copper pipeline part.
EDIT: web Page 33 for the installation manual states that the water supply pipe is 1/4″ OD. You may need a 1/4″ valve. Make sure there are not any burrs in the copper tubing after it is cut by you. Often you’ll look at tids now want to register the sides. In the event that pipeline cutter just isn’t razor- razor- razor- sharp it could mushroom the ends and which will ensure it is appear it is maybe maybe not the right diameter.
On it, preferably set in the wall in plastic box if you have more time and money, the best thing is to run either a 1/2 inch copper line or a 1/2 galvanized line to the back of your refrigerator with a 1/4 inch connection. An alternative cheaper means would be to run a 1/4 inches line through the 1/4 inches connection at your double shut off valve under your drain. Nevertheless, the copper line is really a difficult line and it gets crimped specially when you or another person is careless in going the refrigerator around to completely clean or any.
Making use of two crescent wrenches, some tips about what to complete in the event that you curently have a copper that is hard to your straight back without a turn off valve anywhere in web web site. You can aquire a kit with the right components you will need, 1/4 inches connectors by having a 6 base, 1/4 inch supply hose, who has the 1/4 pea pea nuts on both ends. Carefully take action your self or get yourself a plumber to slice the copper line by having a copper pipeline cutter, a good cut that is clean a few of ins this part of where in actuality the line is released of wall surface or case (so long as it isn’t crimped, you are ok to cut it).
Place the free 1/4 inches nut on backwards in the pipeline, and so the nut covers the ferrel tucked in during the side of the final end associated with pipeline, then, screw regarding the 1/4 inches connector/adjuster about it, aided by the 1/4 inches threads to your 1/4 inches nut regarding the hose, and tighten up, snug, never ever overbearing, ever with any plumbing system. Then link one other end of hose/nut towards the threaded end on the fridge at the end, snug! Keep In Mind! Nevertheless, a very important thing doing whenever you are linking a line to either a tap or ice box or in any case can be, just before put that final connection in the ice box, put that end up in a large bucket and turn it in to clear the type of atmosphere and grub, because that knows just how long it has been sitting. Plus, if you atmosphere into the lines, that is a entire nother hassle, trust in me you will not want! Obtain the atmosphere down! you certainly can do all this your self too! Do not forget to check always every thing for leakages! Best of luck! Now get commemorate you merely conserved your self $150.